HOME


Veriteq - Data Loggers



OverviewHardwareSoftwareApplicationsValidation DocumentationBenefitsFAQSupport & DownloadsRequest info



"Don't fancy Thermocouples ?"
High end Veriteq data loggers are ideal for precise measurement of temperature and humidity, as well as current loops, low voltage and connection of Thermocouples. They can be used independently or as a networked company wide 24/7 monitoring solution with alarm functionality via PC, e-mail or phone.
Highlights:

  • Hybrid technology allows both validation and continuous monitoring with the same unit.
  • Up to 10 (!) years typical battery operating life
  • Available for GxP and FDA regulated operation (VL-Series).
  • Calibration certificates traceable to international standards
  • OPC drivers allow integration into existing systems and equipment.


Predestined for use in every situation where temperature and humidity are critical, such as pharmaceutical, Bio-Tech, clinical, aerospace, calibration labs and many others.

"Hygrothermograph insufficient?"

Two versions of Veriteq data loggers are available; SP-Series (Spectrum) and VL-Series. Both series feature compact, accurate high end data loggers with extremely long battery life. They are easy to use and their modularity allows easy expansion. Loggers can be combined through the viewLinc Software to build a continuous monitoring system with alarm functionality.

The VL-Series was designed specifically to suit pharmaceutical applications requiring validation in FDA/GxP regulated environments. It complies with the requirements of FDA guideline 21CFR11, can generate the required documentation and also provide IQ/OQ logs.

Each data logger is accompanied by a traceable, internationally recognised calibration certificate.

Data Logger for temperature and humidity


Data Logger 2000 - Temperature and Relative Humidity
Validatable high end data logger for temperature and humidity monitoring
  • Internal sensors
  • Measurement Range: -35 to 85°C, 0% RH to 100% RH non condensing
  • Choice of 3 temperature and 3 humidity calibration points, or 5 temperature and 6 humidity calibration points to match ICH requirements.
  • Humidity accuracy up to ±1%RH at 0.05%RH resolution
  • Temperature accuracy up to ±0.1°C at 0.02°C resolution
  • Accuracy of ±2%RH and ±0.15°C guaranteed (!) after first year of deployment
  • 10-year battery operating life
"The Veriteq validation system reduced the time for our temperature mapping work by at least 80%."
- Stephanie Cowan, Pharmaplan Valicor


Technical Specifications
Datasheet

Data Logger 1016/1416 - Temperature
Validatable high end data logger for temperature monitoring with extended temperature range
  • Up to 4 external probes (3m or 7.5m)
  • Temperature Measurement Range: -95°C to +70°C with only one type of sensor
  • Temperature accuracy: ±0.25°C at 0.01°C resolution
  • Accuracy of ±0.35°C guaranteed (!) after first year of deployment
  • 10-year (!) battery operating life


Technical Specifications
Datasheet

Data Logger 1000/1400 - Temperature
Validatable high end data logger for temperature monitoring
  • Internal and/or up to 4 external probes (3m or 7.5m)
  • Temperature Measurement Range: -90°C to +85°C
  • Temperature accuracy up to ±0.1°C at 0.02°C resolution
  • Accuracy of ±0.15°C guaranteed (!) after first year of deployment
  • 10-year (!) battery operating life
"Stick the loggers where you want them and you're done. A lot easier than stringing thermocouples."
- Bill Gervasi, NexMed

"After researching several companies that offer data loggers for validation, the decision to purchase from Veriteq was easy."
- Jean Wilson, GlaxoSmithKline


Technical Specifications
Datasheet

vNet PoE Logger Interface
Reduce Installation Requirements for Environmental Monitoring Systems
Reliable network communications and cost are both important, which is why more and more companies are using Power over Ethernet (PoE) devices in their monitoring applications.
Veriteq's vNet PoE network interface provides easy connectivity with data loggers at a lower cost. The snap-in design streamlines logger connectivity into a small footprint and eliminates wires between separate loggers and PoE devices.
The cost of installing an AC power source at each monitored point is completely eliminated; a significant savings. The vNet PoE integrates the VL and SP recorders without any compromise to accuracy. With the low price of today's network switches that integrate PoE power capability, the decision to use PoE devices is both cost effective and extremely reliable.

Technical Specifications

Data Loggers for special applications


Thermocouple Data Logger 1700 - Temperature
Validatable high end thermocouple data logger for temperature monitoring
  • Accepts up to 4 thermocouples of type J, K, T, E, R or S
  • Temperature Measurement Range: -240°C to +1,760°C
  • 10-year (!) battery operating life


Technical Specifications
Datasheet



Data Logger 1000-VLT - Very Low Temperatures down to -90°C
Validatable high end data logger for monitoring of very low temperatures
  • Internal sensor
  • Temperature Measurement Range: -90°C to +35°C
  • Temperature Accuracy ±1.0°C
  • Accuracy guaranteed (!) after first year of deployment
  • 5-year battery operating life


Technical Specifications
Datasheet

Data Logger 4000 - Current Loop and Voltage
High end data logger for current loop and voltage monitoring
  • Measurement ranges: 0…1V, 0…10V, 4…20mA
  • Single and multi-channel versions available
  • Logging of industry-standard sensors, transmitters and transducers
  • 10-year (!) battery operating life


Technical Specifications
Datasheet





CiK Solutions GmbH
Haid-und-Neu-Str. 7
D-76131 Karlsruhe

Tel.: +49 - (0)721 - 62 69 085-0
Fax: +49 - (0)721 - 62 69 085-99
Pharma - Accessories

Thermocouples
Feed-Thru