Kontakt

Questions? Price info? Technical details?

+49 - (0)721 - 62 69 08 50
or
Send us an enquiry

MSR145WD Wireless Data Logger with BLE, Display & MSR SmartCloud

MSR145WD Wireless Data Logger with BLE, Display & MSR SmartCloud

Data Logger MSR145WD

Wireless monitoring of measured data and an at-a-glance overview of recorded values – these are only some of the conveniences the new MSR145WD wireless data logger has on offer. 

The mini-logger is equipped with Bluetooth Low Energy, a bright OLED graphic display and -optionally- the web-based MSR SmartCloud service for data monitoring from any location. 

 

New

Analogue Inputs
The MSR145WD is now available with 4 or 8 analogue inputs for connecting external sensors. The analogue inputs with freely selectable input configuration can be used for a range of conventional sensors (e.g. conductivity or speed).

3-axis-acceleration sensor with fast peak function
Working range: ±15 g (-20 °C …+65 °C), measurement frequency 1/s (fast peak 800 Hz), storage rate 1/s to every 12 h.

Base Station to transmit the data automatically to the MSR SmartCloud
The base station (BLE receiver box) acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud. You can order it separately, item no. N10115.

MSR145WD Base Station

 

 

Highlights

  • Time-controlled Connectivity
  • Password Protection
  • MSR App
  • up to 5 Air Pressure Sensors

 


The BLE wireless link is of particular advantage in applications that require monitoring of measurements in locations that are difficult to access, such as rotations on a machine. BLE allows the user immediate data visualisation, irrespective of location.

You can retrieve the measured values via your smartphone, receive alarm messages via MSR SmartCloud and share data from multiple MSR145WD data loggers with your team as required.

MSR SmartCloud

 


 

Technical specifications: OLED display

Wireless data logger MSR145WD with OLED display


  • High-contrast, lustrous OLED (organic light-emitting diode) colour display for data and graphical charts
  • Resolution: 96 x 64 pixels
  • Display area: 22.14mm W x 15.42mm H
  • Fast response time: <10 μs
  • Wide viewing angle >160°


 

Technical specifications: Bluetooth Low Energy

 

  • Bluetooth Low Energy (Bluetooth 4.0 Smart) 2.4 GHz
  • Wireless range: approx. 10m
  • Communication with multiple MSR145WD data loggers possible
  • Alarm function, transmission to MSR SmartCloud
  • Free Smartphone app ( iPhone 4S and later, iPad 3 and later, Android)
  • Compatible with Windows or Linux PC  (Bluetooth-Dongle available)
  • Rugged BLE receiver box available as gateway

Smart phone with Bluetooth and MSR app

 


 

 

With a few clicks you are able to select and send us your order or request a no-obligation quotation of your desired MSR145WD.

  1. Select the housing and the corresponding battery.
  2. Select the sensors.
  3. Do you require 4 or 8 analogue inputs?
  4. General technical data on the MSR145WD.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat material Item‑no.
Standard
IP 60
Design housing
with 260 mAh battery,
OLED display and
Bluetooth Low Energy
Data logger MSR145WD with 260 mAh battery, dustproof IP 60 57 x 35 x 17 mm
approx. 27 g
Air PC, not
encapsulated
145WDB25
Error
Design housing
with 900 mAh battery,
OLED display and
Bluetooth Low Energy
Data logger MSR145WD with 900 mAh battery, dustproof IP 60 57 x 35 x 25 mm
approx. 43 g
Air PC, not
encapsulated
145WDB23
Error
Waterproof
IP 67
Design housing
with 260 mAh battery,
OLED display and
Bluetooth Low Energy
Data logger MSR145WD with 260 mAh battery, waterproof IP 67 57 x 35 x 17 mm
approx. 36 g
Air,
various liquids
PC,
encapsulated
145WDB26
Error
Design housing
with 900 mAh battery,
OLED display and
Bluetooth Low Energy
Data logger MSR145WD with 900 mAh battery, waterproof IP 67 57 x 35 x 25 mm
approx. 62 g
Air,
various liquids
PC,
encapsulated
145WDB22
Error

2. Select the sensors.

You can equip the MSR145WD wireless data logger with up to five different internal or external sensors. For either temperature, humidity or air pressure, you can choose whether you wish to provide your data logger with more than one sensor of the same measured parameter.

When selecting sensors, please bear in mind that we are continuously expanding our range of sensor combinations.

Measured parameter /
Measuring/storage rate
Working range /
Accuracy
Internal
sensor
External sensor (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
external: -40...+125 °C
internal: -20...+65 °C

±0.2 °C (-10...+50 °C)
±1 °C (-40...+125 °C)
Item no. T5
Error
Item no. FT5/020
Error

Item no. FT5/100
Error

Item no. FT5/160
Error

Humidity
with integrated temperature

1/s to every 12 h
0...100 % rel. humidity
external: -40...+125 °C
internal: -20...+65 °C

±1.8 % rel. humidity
(10...85 %, 0...+40 °C)
±4 % rel. humidity
(85...95 %, 0...+40 °C)
Item no. H2
Error
Item no. FH2/020
Error

Item no. FH2/100
Error

Item no. FH2/160
Error

Air pressure absolute,
with integrated temperature

1/s to every 12 h
10...2000 mbar absolute
external: -40...+85 °C
internal: -20...+65 °C

±2 mbar
(750...1100 mbar abs.,
+25 °C)
Item no. P5
Error
Item no. FP5/020
Error

Item no. FP5/100
Error

Item no. FP5/160
Error

3-axis-acceleration
(static)

1/s to every 12 h
±15 g
-20...+65 °C

±0.15 g (+25 °C)
Item no. A
Error
Item no. FA/020
Error
Item no. FA/100
Error
Item no. FA/160
Error
3-axis-acceleration
with Fast Peak (800 Hz)


1/s to every 12 h
Item no. A4
Error
Item no. FA4/020
Error
Item no. FA4/100
Error
Item no. FA4/160
Error
Light

1/s to every 12 h
0...65 000 lx
max. sensitivity
at 500 nm
Item no. L2
Error
Item no. FL2/020
Error
Item no. FL2/100
Error
Item no. FL2/160
Error

3. Do you require 4 or 8 analogue inputs?

Should you wish to connect additional third-party external sensors to your MSR145WD datalogger, then please indicate here whether you require four or eight analogue inputs.

Analogue inputs Inputs Input configuration Item no.
Schraubklemme für 8 analoge Eingänge
Measurement/storage rate:
1/s to every 12 h
4 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3,0 V
(4)   0,5...4,5 V / 0...5,0 V
(5)   0...10,0 V / 1,0...6,0 V
(6)   0...12,0 V
(7)   0...24,0 V
Exxxx
Error
8 analogue inputs
(resolution: 12 Bit)
Exxxx&Exxxx
Error

4. General technical data on the MSR145WD.

Memory capacity: Over 1 000 000 measured values.
Key: Set bookmark or start and stop recording.
LED:  
blue:
red:
yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply:
  • Lithium-polymer battery, 260 mAh or 900 mAh.
  • The battery is charged via the USB connection.
Options: Charging station (USB hub) for 7 MSR145WD (item number B47002)
Interface: USB
PC software: Free Setup, Reader, Viewer and Online software (Windows XP/Vista/7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. Thanks to the integrated clock (RTC), data from as many MSR145WD units as required can be synchronised and merged into a single data record.
Operating conditions:
Temperature: -20...+65 °C
Optimum storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145WD complies with EU-Directives RoHS / WEEE.