MSR160 data logger
Four integrated analog inputs, a high measuring rate and the gigantic memory capacity are the outstanding features of the MSR160 data logger, in addition to its small format. The analog inputs of the robust mini logger can be used to connect conventional sensors with analog outputs (e.g. CO2, conductivity, pH etc.).
A switched power supply is also provided. The measuring rate of the versatile data logger is up to 1000/s. On request, the analog measuring device can also be equipped with internal or external temperature, humidity, light and pressure sensors. Using the optional microSD card, you can record and save over a billion measured values with the MSR160. The lightweight device (approx. 80 g) has an anodized aluminium housing and a rechargeable lithium polymer battery with a capacity of 1,000 mAh. All recordings can be quickly transferred to a PC or laptop via a USB interface. The user-friendly software for data recording and analysis is included free of charge.
Highlights
- With smart case housing and clip system!
- Four analog inputs for connecting conventional sensors with analog outputs, switched power supply
- Measurement/storage rate per channel: 1000/s to every 12 h
- Memory capacity over 2 million measured values, with optional microSD card over 1 billion measured values
Configure your MSR160
With a few clicks, you are able to select your desired MSR data logger and send us your request.
- Basic specification and technical data for the MSR160
- Select the input configuration.
- Select the sensors.
- Would you like to expand the memory capacity of your MSR160 to over 1 billion measurement parameters?
1. Basic specification and technical data for the MSR160
Housing |
Technical data | Item no. | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard IP 60 PC, not encapsulated |
|
160B7 Error |
||||||||||||||||||||||||||||
Waterproof IP 67 PC, encapsulated |
160B8 Error |
2. Select the input configuration.
Analogue inputs | Inputs | Input configuration | Item no. |
---|---|---|---|
Including alarm output and input for starting and stopping data recording. |
4 analogue inputs (resolution: 12 bit) |
Select the number of inputs for the respective input configuration: (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0.5...4.5 V / 0...5.0 V (5) 0...10.0 V / 1.0...6.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V |
Exxxx |
3. Select the sensors.
You can select various internal as well external sensors.
Measured parameter / Measuring/ storage rate |
Working range / Accuracy |
Internal sensor |
External sensor (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
external: -40...+125 °C intern: -20...+65 °C ±0.1 °C (-25...+55 °C) ±0,3 °C (-40...+125 °C) |
Item no. T9 Error |
Item no. FT9/020 Error |
Item no. FT9/100 Error |
Item no. FT9/160 Error |
-55...+125 °C ±0.5 °C (-10...+70 °C) ±2 °C (-55...+125 °C) |
only available externally |
Item no. FT2/020 Error |
Item no. FT2/100 Error |
Item no. FT2/160 Error |
|
Relative humidity with integrated temperature 1/s to every 12 h |
0...100 % rel. humidity extern: -40...+125 °C intern: -20...+65 °C ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. Feuchte (80...100 %, +25 °C) |
Item no. H3 Error |
Item no. FH3/020 Error |
Item no. FH3/100 Error |
Item no. FH3/160 Error |
Air pressure absolute, with integrated temperature 1/s to every 12 h |
10...2000 mbar absolute extern: -20...+85 °C intern: -20...+65 °C ±2,5 mbar (750...1100 mbar abs., +25 °C) |
Item no. P5 Error |
Item no. FP10/020 Error |
Item no. FP10/100 Error |
Item no. FP10/160 Error |
0...14 bar absolute -20...+65 °C ±50 mbar (1...10 bar abs., +25 °C) |
Item no. P7 Error |
Item no. FP7/020 Error |
Item no. FP7/100 Error |
Item no. FP7/160 Error |
|
Attitude 1/s to every 12 h |
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
Light 1/s to every 12 h |
0...83 000 lx max. sensitivity at 550 nm |
Item no. L3 Error |
Item no. FL3/020 Error |
Item no. FL3/100 Error |
Item no. FL3/160 Error |
4. Would you like to expand the memory capacity of your MSR160 to over 1 billion measurement parameters?
Please order the expansion slot for plugging-in a standard microSD card here. | Item no. |
---|---|
Expansion slot for microSD card (includes one formatted and ready for use ≥4GB microSD card). Please note that this expansion slot with plugged-in microSD-card only meets the protection category IP60. |
N10006 Error |