- Home
- en
- datalogger-monitoring-systems
- datatrace-products
- micro-flex-logger
Micro Flex RF Temperature Logger
We introduce the new Micro Flex logger for use in validating surface temperature environments.
Its dual probe design provides capability to measure surface and vial temp with one logger or measure two vials or two surface temperatures at one time.
Logger Includes:
- Two 2mm flexible probes
- Standard temperature battery (-40°C to 140°C)
- Low temperature battery (-80°C to -40°C)
- 1 shelf temperature puck attachment

Micro Flex Temperature Data Logger

Micro Flex Temperature Data Logger with Puck
Applications
Used in validation of shelf temperatures in:
- Lyophilization (freeze-drying)
- Shelf Temperature Profiling
- Vial Temperature Measurement
- Stability Chambers
Not just a Lyophilization Logger
DataTrace Micro Flex offers:
- Faster temperature response time
- Shielded, Ultra-flexible silicone probe
- Customized solutions
DataTrace RF Temperature Data Logger - Specifications
Operating Parameters |
|
Operating Temperature | -80°C to +140°C* |
Temperature Accuracy | -40°C to +140°C: ±0.2°C -80°C to -40°C: ±0.35°C |
Resolution | 0.001°C |
Operating Pressure | up to 10 bar |
* Operation below -40°C requires a special battery. The low-temp battery provided by Mesa should be used in this operating range. When the logger is used above 0°C, the standard battery can be used. Please note, the standard battery can be used across the full operating range of the logger, but will severely degraded performance at temperature below -40°C. | |
Wireless |
|
Range | 30 meters Line of Sight |
Radio Frequency | 2.4 GHz range ISM Band |
Hardware |
|
Size |
Width 23.2mm x Length 94mm** |
Weight | 170 grams** |
Material | Stainless steel SAE 316 (1.4401) and ULTEM or PCTFE |
Probe/Hub | Flex Cable Standard Lengths: 457.2mm; 609.6mm; 762mm; 914.4mm Tip Length: 37.5mm Tip Diameter: 2mm |
** Size and weight are shown for Logger body only | |
Monitoring Parameters |
|
Memory | 8,192 time/temperature observations or 16,384 observations in compressed data mode |
Sample Rates | Operator programmable • 5 sec. to 1 hr interval with radio • 1 sec. to 1 hr interval without radio |
Others |
|
Calibration | Factory calibrated (NIST traceable) / Field calibration |
Battery Type | Type AA Lithium (field-replaceable) |
Battery Life | 6 months to 1 year (depending on usage) |
Battery Weight | Standard Temperature Battery: 17 grams Low Temperature Battery: 19 grams |
Clock Accuracy | 10 seconds per 24 hours (25°C) |
Certifications | ATEX (for intrinsic safety) FCC Class B digital device (Part 15 compliant) |
|